Main Features

  • DSP Based Technology:
  • Advanced MPPT Technology:
  • Bulit In Isolation Transformer:
  • High Surge Capability:
  • Reduce Battery Sulphation:

Solar Inverters (1-10KVA)(MPPT)

Features & Applications

  • DSP Based Technology
  • Advanced MPPT Technology
  • Bulit In Isolation Transformer
  • Enhance 30% more Battery Life
  • Upto 60% Energy Savings on electricity Bills
  • High Surge Capability
  • Reduce Battery Sulphation

Download Datasheet

Model No. SBH6000 SBH7500A SBH7500B SBH10000A SBH10000B
Ratings 6.0 KVA 7.5 KVA 7.5 KVA 10 KVA 10 KVA
Switching Element IGBT
Inverter Charger Topology Boost
Solar Charger Topology IGBT Based MPPT Buck Converter
Controller 16-Bit dsPIC
Max. Battery Capacity 200AH
Inverter Priority Mode [Grid, Solar, Battery] G»S»B S » G » B (Default)
S»G»B
S»B»G
PV Parameters (With Inbuilt MPPT Charge Controller)
Solar Input Voltage Range(Min - Max) 165V-400V 165V-400V 210V-500V 210V-500V 315V-650V
Maximum Solar Current 50A 75A 65A 80A 55A
Nominal DC 96V 96V 120V 120V 180V
Inverter Parameters
Output Voltage 230V ± 2% , 1ɸ
Maximum Output Current 20A 25A 25A 33A 33A
Output Frequency 50Hz ± 1
Isolation Transformer Provided Inbuilt
Crest Factor 3:1
Output Waveform Pure Sinusoidal
THD Linear Load < 3%
Non Linear Load < 5%
Overload > 100%, 30 Seconds
Inverter Efficiency > 85%
Changeover Time Battery to Mains < 10ms
Mains to Battery < 12ms
Protections & Alarm Over and undervoltage Solar/Grid, Over Load, Battery Low &High , Short Circuit, PV Reverse, Over Temperature
Remote Monitoring Port RS232/RS485 (Modbus) Optional
Grid Input Parameters
Nominal Grid Voltage 230V, 1ɸ
Nominal Grid Frequency 50Hz
Input Low Cut Voltage 170V ± 5V
Input Low Recovery Voltage > 180V ± 5V
Input High Cut Voltage 270V ± 5V
Input High Recovery Voltage < 260V ± 5V
Input Frequency Range/td> 47Hz - 53Hz
Battery Parameters
Battery Charging Grid 12A ± 1A
Solar 15A ± 1A
Boost Voltage Grid 116V ± 1V 116V ± 1V 145V ± 1V 145V ± 1V 217V ± 2V
Solar 117V ± 1V 117V ± 1V 147V ± 1V 147V ± 1V 220V ± 2V
Float Voltage Grid 108V ± 1V 108V ± 1V 135V ± 1V 135V ± 1V 202V ± 2V
Solar 109V ± 1V 109V ± 1V 137V ± 1V 137V ± 1V 204V ± 2V
Equalization Voltage Grid 124V ± 1V 124V ± 1V 160V ± 1V 160V ± 1V 232V ± 2V
Solar 125V ± 1V 125V ± 1V 162V ± 1V 162V ± 1V 234V ± 2V
Battery Low Buzzer 86V ± 1V 86V ± 1V 107V ± 1V 107V ± 1V 160V ± 2V
Battery Low Cut 85V ± 1V 85V ± 1V 105V ± 1V 105V ± 1V 157V ± 2V
Battery Low Reconnect 94V ± 1V 94V ± 1V 117V ± 1V 117V ± 1V 177V ± 2V
Battery High 136V ± 1V 136V ± 1V 170V ± 1V 170V ± 1V 255V ± 2V
Display Parameters LCD display for Input & Output - Voltage, Current & Frequency, Battery - Voltage & Current, Solar Voltage & Current
Display Alarms Output load Percentage, Overload time, Grid - On / Fail / High / Low , DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Load, Temperature
Switchgear Grid MCB, Battery MCB, Solar MCB, Manual Bypass Switch
Enclosure IP 20
Operating Temp. 0 to 40 Deg C
Humidity Upto 95% Rh (non-condensing)
Cooling Forced Air
Noise < 55 dB, distance 1 meter
Dimensions in mm (L X W X H) 600 X 350 X 480 700 X 350 X 570
Weight(Approx Kgs) 75 Kg 78 Kg 78 Kg 90 Kg 90 Kg
Bypass Switch Satatic Switch
Wheels Provided

Our Satisfied Clients

some of our great clients and their review

SunGarner deploys world-class technology to design, install and commission benchmark solar projects. We avail their services including design, engineering & implementation of solar Off Grid and On Grid Power Plants. It has been more than 5 years now and they are delivering with the latest technology.

#

Mr. Sunil Sharma Group Vice President, Modi Xerox

SunGarner has a dynamic in-house R&D Department with an experienced back-up, providing customized solutions on problems pertaining to the energy needs of a wide variety of Industrial, Commercial and Residential establishments in several areas. I am happy with their after-sales service too.

#

Mr. Vinod Ajitsaria Managing Director, V N Dyers & Textiles

#
#
#
#
#
#
#
#
#
#